Skip to main content
Trade Bidding

Window and Glazing Contractor Bidding Guide

December 16, 2025Updated October 28, 20269 min readConstructionBids.ai TeamReviewed by Haithum Abdelfattah, Founder & CEO
Back to Blog

At a glance

A commercial glazing bid turns on a few spec items: whether the system is curtain wall or storefront, which field water tests are required, where safety glazing is required, how energy ratings are certified (NFRC), whether Buy America applies to the glass, and who engineers and stamps the wall.

What you need to know

  • Curtain wall runs past floors and anchors through its verticals; storefront runs floor to structure and anchors at the perimeter. Price them as different systems.
  • Field water tests are a line item: AAMA 501.2 is a diagnostic check, while AAMA 503 and ASTM E1105 test against specified performance.
  • Codes that require NFRC ratings accept the NFRC label certificate, not manufacturer data, so budget for certification on custom systems.

Ready to find bids that match your trade?

Thousands of verified public-bid sources. Cancel anytime.

Start 7-Day Free Trial

Curtain wall or storefront: price the right system

The two systems look alike in elevation but are built and anchored differently. The California Division of the State Architect (DSA) defines them in its interpretation of regulations for window wall systems:

Curtain wallStorefront
FramingNon-load-bearing; vertical members run past intermediate floorsVertical members typically run between the top of the floor and the structure above
AnchoringThrough the curtain wall verticals, usually at the building exteriorAt the perimeter of the opening
DSA reviewMultistory curtain walls are never exempt from structural reviewReview required if any element spans more than 10 feet

The anchoring difference is where estimates go wrong. Because a curtain wall runs past the floors and anchors through its verticals, slab edge conditions, embeds and fire-safing at each floor become part of the scope conversation. Storefront anchors into the opening, so the opening's framing and its tolerances matter more. Read the drawings for which system each elevation actually calls for, especially at lobbies where both meet.

The same DSA document groups curtain walls, storefronts, windows and other glass walls as "window wall systems" and defines span as the clear distance between supports along the framing. On California school and state projects, any element spanning more than 10 feet triggers DSA structural review.

Field water testing: a line item, not a footnote

When a specification requires field testing of installed curtain wall or storefront, the standard it names matters. The tests differ in purpose, and so do their costs:

  • AAMA 501.2 is a quality-assurance and diagnostic water check of installed storefronts, curtain walls and sloped glazing. FGIA's description of an earlier edition says it is not meant to test rated or specified performance under wind-driven rain, and points to AAMA 503 for that.
  • AAMA 503 evaluates newly installed storefronts, curtain walls and sloped glazing during construction, to give reasonable assurance that the products will perform to the specified or rated air leakage and water penetration levels.
  • ASTM E1105 determines the water penetration resistance of installed windows, curtain walls, skylights and doors by spraying water on the outdoor face while holding a higher static air pressure outside than inside. It does not measure air infiltration.

ASTM notes that testing during installation lets fabrication or installation errors be found and corrected before the whole wall is complete. It also leaves the test pressure to the specifier, and says a test should not run when wind gusts swing the pressure more than 10 percent from the specified value.

For the bid, count the number of test areas the specification requires, who provides the testing agency, and who pays for retests after a failure. Each retest means mobilizing the testing crew and sometimes a lift again.

Safety glazing locations

Safety glazing requirements come from two places:

  • Federal: 16 CFR 1201. The Consumer Product Safety Commission standard covers glazing in doors, storm doors, sliding glass doors, and bathtub and shower doors and enclosures, including in "school, public, or other buildings." Its requirements for glazed panels were revoked in 1980, and wired glass in fire assemblies required by a fire ordinance is exempt.
  • The building code's hazardous locations. Under the 2015 International Building Code, as New Jersey's code assistance unit explained, a window is a hazardous location only when all four conditions are met: a pane larger than 9 square feet, its bottom edge less than 18 inches above the floor, its top edge more than 36 inches above the floor, and a walking surface within 36 inches. Glazing in doors, next to doors, near wet areas, at stairs and in guards has separate rules.

Read the glazing schedule and the door elevations together. Each pane in a hazardous location needs safety glazing and a manufacturer's mark naming the standard it complies with, so a schedule that calls out plain "clear" glass at a sidelite is a question to ask before bid day.

Energy ratings: NFRC certification

Energy codes set U-factor and solar heat gain limits for fenestration and say how the values must be rated. Seattle's 2021 energy code, for example, requires U-factor ratings under NFRC 100, and SHGC and visible transmittance under NFRC 200 by an accredited independent laboratory. Products without a label get the code's default values.

The National Fenestration Rating Council says its Commercial Label Certificate is the only way to meet codes that require NFRC-certified ratings, and that manufacturer data and lab simulation reports are not a substitute. Code officials are told to ask for the certificate before signing off on the project. California's Energy Commission classes storefront and curtain wall as "site-built" fenestration, field-assembled from factory products, which still need certified ratings.

NFRC moved its commercial program to a new method in 2025 and retired its former program (CMA) in May 2026. If your supplier's ratings were done under the old program, confirm what the project's code official will accept.

Buy America on federally funded work

On federally funded infrastructure, which includes buildings, the Build America, Buy America (BABA) rules in 2 CFR 184 apply. They matter to glazing in three ways:

  • Glass is a listed construction material, alongside non-ferrous metals such as aluminum.
  • US-made glass means every manufacturing process, "from initial batching and melting of raw materials through annealing, cooling, and cutting," happened in the United States.
  • Classification happens at the site. An item is classified by its status when it is brought to the work site, and it has to meet the rule for only one category. The preference flows down to all subawards, contracts and purchase orders.

The regulation does not say whether an assembled curtain wall unit or window is a construction material or a manufactured product. That classification changes which test applies, so get the owner's answer in writing before you price imported glass or unitized panels.

Who engineers the wall

Whether the glazing contractor's engineer designs the curtain wall, and who is allowed to, depends on the owner and the jurisdiction:

  • Seattle requires curtain wall shop drawings designed by a structural engineer licensed in Washington, or a civil engineer with at least five years of curtain wall structural design. Every shop drawing sheet is stamped by the design engineer, and high-rise projects need an ICC-ES report for specialty anchors.
  • Virginia's state building program considers delegated design for curtain walls and storefront on request, but only when the agency approves it in the owner's contract with the architect. Otherwise, specifications that require the contractor to provide engineering are not acceptable, and the architect stays responsible for how delegated systems fit the building.
  • California DSA requires deferred-submittal window wall documents to be stamped and signed, with complete details of every mullion connection and connection to the structure, and DSA approves them.

If the specification delegates design, your price needs the engineer's fee, the calculation and shop drawing time, and the review cycles before fabrication. The construction submittals guide covers how shop drawing reviews run, and the shop drawings definition explains what reviewers expect.

A glazing bid checklist

CheckWhere to find it
Curtain wall vs storefront at each elevationElevations, wall sections, anchor details
Field water tests: which standard, how many areas, who pays retestsGlazing specification, testing section
Safety glazing locationsGlazing schedule, door elevations, code analysis
NFRC certification path for each productEnergy compliance forms, glazing specification
Buy America: does it apply, and how are assembled units classified?Funding source, supplementary conditions
Delegated design, the engineer's license state, and stampingGlazing specification, the jurisdiction's shop drawing rules
Slab edge, embeds and fire-safing at each floorStructural and fire-rated assembly drawings

Scope gaps at the glazing boundary can sit with the trades next to it, such as sealant to adjacent cladding, fire-safing and blocking. Our scope gaps guide covers how to level those quotes.

Sources

All sources were read on October 28, 2026.

Frequently Asked Questions

What is the difference between curtain wall and storefront?

In the California Division of the State Architect's definitions, a curtain wall is a non-load-bearing system whose vertical framing members run past intermediate floors and anchor to the building through those verticals. A storefront's vertical members typically run between the top of the floor and the structure above, and the system anchors at the perimeter.

Which field water tests do glazing specifications require?

Common ones are AAMA 501.2, a quality-assurance and diagnostic water check of installed storefronts, curtain walls and sloped glazing, and AAMA 503 or ASTM E1105, which test installed work against specified or rated performance. The specification sets the test pressure and how many areas are tested.

Does Buy America apply to glass on federally funded projects?

Under the Build America, Buy America rules in 2 CFR 184, glass is a listed construction material, and US-made glass means every manufacturing process from batching and melting through annealing, cooling and cutting happened in the United States. An item is classified by its status when it arrives at the site. Confirm with the owner how an assembled glazing unit is classified.

Who engineers a curtain wall on a public project?

It depends on the owner and the jurisdiction. Seattle requires curtain walls to be designed by a Washington-licensed structural engineer, with every shop drawing sheet stamped. Virginia's state building program allows delegated design for curtain walls and storefront only when the agency approves it in the owner's contract with the architect.

Related Articles

Complete your stack with public & government bids.

ConstructionBids.ai fills the public-procurement gap with official source links, matching, alerts, risk review, and bid-decision workflow.

7-day free trialCancel anytimeThousands of verified sources